| Solid-wedge gate valve | A solid wedge travels linearly between the seats; a multi-turn actuator drives the stem to open or close. | General-purpose on/off isolation in compatible liquid, gas, and utility services. | Use an actuator sized for the valve’s required thrust or torque, travel, and operating conditions. | IP66: dust-tight and protected against powerful water jets. IP67: dust-tight and protected against temporary immersion under the specified test conditions. | A common isolation design; not intended for routine throttling. Suitability depends on pressure, temperature, fluid, and installation. |
| Flexible-wedge gate valve | A one-piece wedge with a flexible section can accommodate some seat and body movement while moving linearly. | Isolation duties where thermal changes or piping conditions make wedge flexibility useful. | Multi-turn operation; actuator output and seating limits should follow the valve manufacturer’s requirements. | An IP rating applies to the tested enclosure, such as the actuator housing; it does not rate the valve’s pressure boundary. | Check the specified materials and service limits. The enclosure rating alone does not establish chemical or corrosion resistance. |
| Split-wedge gate valve | Two wedge halves seat against the valve body; the gate moves linearly under multi-turn operation. | Selected isolation services where the split-wedge arrangement is specified for the application. | Electric actuation must match stem configuration, required travel, and valve operating loads. | IP66 and IP67 are separate enclosure protection classifications under IEC 60529, not guarantees of suitability for every outdoor environment. | Confirm the intended pressure, temperature, and media range rather than selecting by gate style alone. |
| Knife gate valve | A thin, blade-like gate moves linearly through the flow path; designs vary by seat and body construction. | Commonly selected for certain slurry, pulp, or solids-handling duties, subject to the design and process conditions. | Often uses a multi-turn electric actuator; required force can be affected by solids, differential pressure, and packing. | The IP code describes protection against ingress into the rated enclosure; it does not describe the valve’s ability to handle process solids. | Verify solids characteristics, shutoff expectations, seat type, and pressure limits for the specific design. |
| Parallel-slide gate valve | Parallel sealing elements move linearly to open or close the passage; construction details vary by design. | Used in specified isolation applications, including some high-temperature or power-service designs. | Select the actuator for the particular stem, travel, operating load, and required control arrangement. | An IP67 claim covers temporary immersion only under the applicable IEC 60529 test conditions; it does not mean continuous submersion is permitted. | Check the valve’s design standard and process rating; enclosure ingress protection is a separate specification. |