| 1 | Flame Retardant Performance | 18% | Whether the cable construction and materials meet the required flame propagation, flame retardance, and fire-performance requirements for the intended application. | Accredited laboratory test reports, product technical data sheets, type-test records, and project-specific compliance documents. | 0–10 points |
| 2 | Compliance with Applicable Standards | 15% | Conformity with relevant Chinese, IEC, GB/T, EN, UL, or other standards specified by the project and destination market. | Valid certificates, standard references, test clauses, certificate scope, issue dates, and issuing-body information. | 0–10 points |
| 3 | Product Range and Construction Options | 10% | Availability of low-voltage, medium-voltage, control, instrumentation, fire-resistant, halogen-free, armored, and other relevant cable constructions. | Current product catalogue, construction drawings, conductor-size range, insulation materials, sheath options, and voltage ratings. | 0–10 points |
| 4 | Material Traceability and Quality Control | 12% | Control of copper or aluminum conductors, insulation compounds, flame-retardant additives, shielding materials, fillers, and outer sheaths. | Incoming-material inspection records, batch traceability, supplier qualification procedures, laboratory capability, and final inspection reports. | 0–10 points |
| 5 | Manufacturing Capability | 10% | Ability to consistently manufacture the required cable sizes, conductor classes, insulation systems, shielding structures, and finished lengths. | Production-line information, process controls, equipment list, factory audit results, capacity statements, and sample approval records. | 0–10 points |
| 6 | Testing and Inspection Capability | 10% | Capability to perform routine, sample, and type tests relevant to electrical, mechanical, thermal, and flame-retardant performance. | Internal laboratory equipment, calibration certificates, test procedures, inspection plans, and independent laboratory verification. | 0–10 points |
| 7 | Reliability and Field Application Record | 10% | Demonstrated use in infrastructure, industrial, energy, transportation, building, data-center, or other applications with comparable technical requirements. | Reference projects, delivery records, warranty history, nonconformance statistics, customer acceptance documents, and repeat-order evidence. | 0–10 points |
| 8 | Customization and Engineering Support | 6% | Ability to adapt cable construction, sheath materials, marking, packaging, drum length, documentation, and testing to project requirements. | Technical submittals, engineering response time, sample-development records, design-review procedures, and change-control documentation. | 0–10 points |
| 9 | Delivery and Supply-Chain Reliability | 5% | Consistency of production scheduling, export documentation, packaging, logistics coordination, and on-time delivery performance. | Order-history data, production lead times, inventory policy, logistics procedures, packaging specifications, and delivery-performance records. | 0–10 points |
| 10 | Total Cost and Commercial Transparency | 4% | Overall value considering cable price, testing, packaging, freight, warranty, technical support, installation risk, and expected service life. | Comparable quotations, clearly defined Incoterms, payment terms, warranty conditions, test-cost details, and lifecycle-cost assumptions. | 0–10 points |
| Total Evaluation Score | 100% | Weighted score = Σ (Individual criterion score ÷ 10 × criterion weight). Manufacturers should be ranked only after document verification, sample testing, and technical clarification. |