| Nominal Voltage | Operating voltage required by the main electronics, motors, sensors, and communication modules. | Select a battery voltage that matches the product power architecture. A single LiPo cell is commonly used directly, while multiple cells in series may be required for higher-voltage systems. | One cell: 3.7 V nominal, 4.2 V fully charged. Two cells in series: 7.4 V nominal, 8.4 V fully charged. | Confirm the minimum and maximum input voltage accepted by every critical circuit. A voltage regulator may be required when the battery voltage does not match the load. |
| Continuous Operating Current | Average current consumed during the normal operating mode. | Measure or estimate the current of each subsystem, then add the values used at the same time. Include a design margin of approximately 20–30%. | Example: electronics 0.35 A + display 0.25 A + wireless module 0.15 A = 0.75 A; recommended continuous rating: at least 0.90–0.98 A. | Use measured current under actual operating conditions whenever possible. Average current is more important than standby current when calculating normal runtime. |
| Peak Current | Highest current drawn during motor startup, radio transmission, camera activation, data processing, or other short-duration events. | Identify the maximum current and its duration. Select a battery and protection circuit that can safely support the peak without excessive voltage drop. | Small portable products may draw 1.5–3 A briefly; motor-driven products may require substantially higher startup current. | Peak current should be evaluated together with wire resistance, connector rating, protection limits, and battery internal resistance. |
| Capacity | Required operating time and average load current. | Estimated capacity (mAh) = average current (mA) × required runtime (hours) ÷ usable-capacity factor. | For a 500 mA average load and 4-hour target runtime, using an 0.80 usable-capacity factor: 500 × 4 ÷ 0.80 = approximately 2,500 mAh. | Usable capacity is reduced by high discharge rates, low temperatures, battery aging, cutoff voltage, and conversion losses. |
| Discharge Rating | Continuous and peak current demand of the product. | Required continuous C-rating = continuous current ÷ battery capacity in amp-hours. Required peak C-rating = peak current ÷ battery capacity in amp-hours. | A 2,000 mAh battery supplying 4 A continuously requires at least 2C continuous capability. Additional margin is recommended. | Do not select a battery using the advertised maximum value alone. Verify the continuous rating, pulse duration, thermal conditions, and test method. |
| Runtime Profile | Percentage of time spent in active, idle, sleep, transmission, charging, and high-load modes. | Calculate a weighted average current using the duration of each operating state. | Example: 1 A for 20% of the time, 0.3 A for 50%, and 0.05 A for 30% gives a weighted average of 0.365 A. | A duty-cycle calculation is generally more accurate than using the highest or lowest current alone. |
| Charge Voltage and Method | Required charging voltage, charge current, charge time, and available charging interface. | Use a charger designed for the selected cell configuration and chemistry. Standard lithium-polymer cells are normally charged using a constant-current/constant-voltage profile. | Single-cell LiPo charging terminates at 4.2 V. A commonly used charge current is around 0.5C to 1C when permitted by the cell specification. | Charging must be controlled by an appropriate charger IC. Never charge a LiPo battery with an unregulated voltage source. |
| Charge Time | Maximum acceptable charging duration and product availability between uses. | Approximate charge time depends on capacity, charge current, battery condition, and the constant-voltage phase. The final phase usually takes longer than the constant-current phase. | At 0.5C, a complete charge commonly takes more than 2 hours; actual time varies by battery and charger settings. | Fast charging increases thermal stress and may reduce service life. The battery manufacturer’s specified charge rate should not be exceeded. |
| Physical Size | Maximum allowable length, width, thickness, connector location, and mounting space. | Reserve clearance for dimensional tolerance, swelling protection, wiring, insulation, and assembly variation. | Allow additional space around the pouch rather than compressing it inside the enclosure. | LiPo pouch cells should not be punctured, folded sharply, compressed, or exposed to edges that may damage the protective film. |
| Weight Limit | Maximum battery mass allowed by the product, especially for wearable, handheld, or airborne equipment. | Compare required watt-hours with the available battery mass and volume. Energy = nominal voltage × capacity in amp-hours. | A 3.7 V, 2.5 Ah battery stores approximately 9.25 Wh before system losses. | Higher capacity generally increases weight and size. Select the smallest battery that meets runtime, current, safety, and aging requirements. |
| Operating Temperature | Minimum and maximum ambient temperatures during operation. | Define the complete temperature range, including storage, charging, and operation. Validate performance at the coldest and hottest expected conditions. | Many LiPo cells operate near 0–45°C while charging and approximately −20–60°C while discharging, but the exact limits depend on the cell specification. | Charging at sub-freezing temperatures can cause lithium plating and permanent damage. Use temperature monitoring where cold charging is possible. |
| Thermal Conditions | Heat generated by the battery, load electronics, charger, and surrounding components. | Estimate heat sources and test the battery under maximum continuous load, peak load, and charging conditions. | High current, high ambient temperature, and restricted airflow increase battery temperature. | Keep the battery away from heaters and provide a safe thermal path. A temperature sensor or thermal cutoff may be required. |
| Voltage Drop | Lowest acceptable voltage at the product input during peak load. | Evaluate battery internal resistance, cable resistance, connector resistance, and protection-circuit resistance under peak current. | Higher-current pulses create larger voltage drops, particularly when the battery is cold or partially discharged. | If the voltage falls below the system’s undervoltage threshold, the product may reset even when usable battery capacity remains. |
| Protection Requirements | Risk of overcharge, over-discharge, overcurrent, short circuit, and abnormal temperature. | Define whether protection is integrated into the battery pack, the product circuit, or both. | Common protection functions include overcharge cutoff, over-discharge cutoff, overcurrent protection, short-circuit protection, and temperature protection. | Protection thresholds must be compatible with the product’s peak current and operating voltage. Protection is not a substitute for a suitable battery design. |
| Cell Balance | Number of cells connected in series and required consistency between cells. | Use a suitable battery-management or balancing circuit for multi-cell series packs. | Two or more cells in series require monitoring of individual cell voltages during charging. | Cell imbalance can cause one cell to overcharge or over-discharge even when the total pack voltage appears normal. |
| Storage Conditions | Expected storage duration, temperature, humidity, and state of charge. | Store the battery in a cool, dry location at the storage charge level specified for the selected cell. | Long-term storage is commonly performed at a partial state of charge rather than fully charged; periodic inspection is recommended. | Avoid storing damaged, swollen, wet, or hot batteries. Check the voltage and physical condition before returning a stored battery to service. |
| Cycle Life Target | Required number of charge and discharge cycles over the product lifetime. | Set acceptable remaining capacity, operating depth of discharge, charge rate, discharge rate, and temperature limits. | Cycle life varies widely; shallow discharge, moderate temperatures, and lower charge rates generally improve service life. | Do not compare cycle-life figures unless the test conditions and end-of-life capacity criterion are equivalent. |
| Connector and Wiring | Current level, mating cycles, assembly method, cable length, and available installation space. | Select connectors and wires with adequate continuous and peak current ratings, insulation, strain relief, and polarity control. | Wire gauge must be selected according to current, length, allowable voltage drop, insulation temperature, and installation method. | Loose connections and undersized wires can create resistance, heating, intermittent resets, or fire hazards. |
| Safety and Validation | Product category, transport needs, regional requirements, abuse conditions, and production quantity. | Plan electrical, mechanical, thermal, charging, abuse, and transportation validation before mass production. | Typical testing may include short-circuit protection, overcharge, over-discharge, vibration, drop, thermal exposure, and enclosure compatibility. | Use documented test limits and traceable battery specifications. Regulatory and transportation requirements vary by market and product type. |