| Broadband Internal Sensor | 300 MHz–1.5 GHz | Typically −65 to −75 dBm | Wideband detection of diverse UHF discharge signals | Installed through a dedicated enclosure or inspection port | Usually IP65–IP67 when correctly sealed | Visual inspection and connector checks every 6–12 months | 10–15 years in a controlled enclosure | 3 / 5 | Permanent monitoring of gas-insulated switchgear and enclosed assets |
| External Directional Sensor | 500 MHz–1.5 GHz | Typically −55 to −65 dBm | Localized detection with improved source direction estimation | Magnetic, clamp-on, or temporary surface mounting | Often IP54–IP65, depending on housing and cable connection | Clean sensing surface and inspect mounting hardware before use | 8–12 years with careful handling | 2 / 5 | Portable surveys, commissioning, troubleshooting, and source location |
| High-Gain Cavity-Coupled Sensor | 800 MHz–1.8 GHz | Typically −70 to −80 dBm | High sensitivity for weak signals in shielded compartments | Integrated into a dedicated access point or inspection window | Typically IP65–IP67 after enclosure validation | Periodic seal, connector, and signal-path verification | 10–15 years under stable thermal and mechanical conditions | 4 / 5 | Critical assets where early detection of low-level discharge is essential |
| Compact Wideband Probe | 300 MHz–2.0 GHz | Typically −50 to −60 dBm | Broad signal capture with moderate localization capability | Handheld probe or temporary test connection | Commonly IP54–IP65 | Clean probe face, inspect cable strain relief, and verify calibration annually | 5–10 years depending on field use and handling | 2 / 5 | Routine field testing, asset screening, and maintenance teams |
| Outdoor-Rated Remote Sensor | 400 MHz–1.5 GHz | Typically −55 to −70 dBm | Continuous monitoring across exposed or semi-exposed equipment | Fixed bracket, weatherproof cable route, and remote acquisition unit | Typically IP66–IP68 with UV-resistant sealing | Annual enclosure, grounding, cable, and surge-protection inspection | 8–12 years, subject to weather and surge exposure | 4 / 5 | Unattended monitoring at substations, outdoor switchyards, and remote sites |
| Multi-Sensor Array | 300 MHz–1.8 GHz | Typically −65 to −75 dBm per channel | High-confidence detection, triangulation, and source localization | Multiple fixed sensors with synchronized acquisition hardware | IP65–IP67 for sensors; system rating depends on the enclosure | Channel checks, time-synchronization verification, and annual calibration | 10–15 years with planned electronics replacement | 5 / 5 | Large or highly critical installations requiring reliable fault localization |