| Process fluid and phases | Identify the liquid, gas, solids, water content, contaminants, and whether the screen is continuously or intermittently wetted. | Material performance can differ substantially between dry gas, aqueous service, multiphase flow, and deposits or stagnant zones. | Use representative process composition and credible operating and upset cases; assess deposits, crevices, and areas with limited circulation. |
| General corrosion | Determine pH, temperature, pressure, chloride concentration, oxidizing species, and relevant acids or solvents. | Stainless steels, duplex stainless steels, nickel alloys, and nonmetallic materials have different limits for uniform corrosion, pitting, crevice corrosion, and stress-corrosion cracking. | Check corrosion data for the actual chemistry and temperature. Consider corrosion allowance, cleaning chemicals, fabrication condition, and inspection access. |
| H₂S exposure and sour-service status | Establish H₂S concentration or partial pressure, total pressure, water phase, pH, temperature, and the applicable service conditions. | H₂S in a wet environment can create risks of sulfide stress cracking (SSC), hydrogen-induced cracking (HIC), and other hydrogen-related damage mechanisms. | Evaluate the defined environment against the applicable ISO 15156 requirements and limits. Do not decide sour-service suitability from H₂S concentration alone. |
| Carbon and low-alloy steels | Record material grade, product form, heat treatment, hardness, strength, weld condition, and any sour-service qualification requirements. | These steels may be viable in specified sour environments when the relevant ISO 15156-2 requirements are met. Hardness, microstructure, tensile stress, and fabrication details can affect cracking susceptibility. | Confirm compliance for the specific material and environment; include welds, heat-affected zones, cold work, and hardness control in the specification and quality plan. |
| Corrosion-resistant alloys (CRAs) | Identify the exact alloy composition and product form, along with temperature, H₂S, chloride, pH, and other environmental limits. | ISO 15156-3 covers CRAs and other alloys. Austenitic stainless steels, duplex grades, and nickel alloys are not interchangeable; susceptibility to localized corrosion or cracking depends on environment and material condition. | Verify that the specific alloy and condition are permitted for the stated environment under the applicable ISO 15156-3 provisions. Check fabrication, welding, and any restrictions on cold work or hardness. |
| Screen construction and aperture | Define opening size, wire or perforation geometry, open area, support arrangement, differential pressure, flow rate, and expected solids loading. | Mesh or slot geometry affects pressure drop, particle retention, erosion, plugging, and mechanical strength. A corrosion-resistant alloy does not by itself ensure adequate screen performance. | Size openings from process separation requirements and verify structural capacity at normal, startup, shutdown, and blocked-screen conditions. |
| Erosion, abrasion, and fouling | Assess particle type, concentration, hardness, velocity, flow direction, and the potential for scale, biofouling, or deposits. | High-velocity solids can remove protective films and accelerate local metal loss. Fine openings may increase plugging and differential pressure. | Review erosion and plugging risks together with corrosion; consider replaceability, cleaning method, and inspection intervals. |
| Fabrication and joining | Specify forming, welding or brazing, surface finishing, heat treatment, and cleaning requirements for the selected material. | Fabrication can change residual stress, hardness, microstructure, and corrosion resistance. Dissimilar-metal joints can also introduce galvanic or fabrication concerns. | Qualify procedures and inspection requirements for the actual material and service. Include weld details and post-fabrication condition in sour-service verification where applicable. |
| Operating envelope and lifecycle | Document design and operating limits, excursions, planned service life, maintenance access, and consequences of screen failure. | Material suitability must cover credible transients as well as steady-state operation. A change in fluid composition or operating conditions can invalidate an earlier selection. | Maintain traceable material records and reassess selection after changes to H₂S, water chemistry, temperature, pressure, or process duty. |
| Standards and documentation | Identify the governing project specifications, equipment codes, material standards, and required edition of ISO 15156. | ISO 15156-1 provides general principles; Part 2 addresses carbon and low-alloy steels; Part 3 addresses CRAs and other alloys. | Record the environmental basis, material condition, applicable limits, qualification evidence, and any project-specific requirements. Obtain review by a qualified materials or corrosion specialist for demanding service. |