| Apparent foam density | Determine mass per volume using ISO 845. Density = mass ÷ volume. | Example coupon: 300 × 150 × 80 mm = 0.0036 m³. Mass = 180 g (0.180 kg). Density = 0.180 ÷ 0.0036 = 50.0 kg/m³. | Check that the system meters the required components consistently and supports the production process used to achieve the specified foam density. | ISO 845 describes a density measurement method; it does not prescribe a suitable density for every pillow core. |
| Density comparison across samples | Measure separate, representative specimens using the same documented sampling and test procedure. | Illustrative results: Sample A, 180 g → 50.0 kg/m³; Sample B, 177 g → 49.2 kg/m³; Sample C, 184 g → 51.1 kg/m³. Each specimen volume: 0.0036 m³. | Ask for repeatable component metering, clear calibration procedures, and production records that can be linked to each batch. | Compare results with the buyer’s own product specification and sampling plan, rather than treating these example values as a standard tolerance. |
| Indentation Force Deflection (IFD) | Measure according to ASTM D3574, Test B1, using the selected test configuration and a documented indentation level. | Illustrative result: 12.0 lbf at 25% indentation for a tested specimen. Record the specimen details, conditioning, test setup, indentation level, and force. | Confirm that the machine can deliver consistent formulation and process conditions. Request trial runs using the intended foam system and pillow-core design. | IFD depends on formulation, specimen preparation, conditioning, and test setup. A single IFD value is not a universal pillow-comfort rating. |
| Fill-mass repeatability | Weigh a series of filled cores at the intended production settings and record each result. | Record the target mass, individual core masses, mean, range, and test conditions for each trial. | Evaluate dosing accuracy, control stability, recipe settings, and the ease of checking or recalibrating the metering system. | Set the acceptance limit from the finished-product specification; ISO 845 and ASTM D3574 do not set a filling-machine mass tolerance. |
| Mixing and process control | Review component ratio, flow or delivery settings, operating records, and consistency between trial runs. | Document the formulation ratio and operating settings used for each foam batch; verify them against the foam-system supplier’s process instructions. | Look for suitable metering range, controllable delivery, repeatable mixing, and accessible records for troubleshooting. | The machine supports process consistency, but foam chemistry and curing conditions also influence density and IFD. |
| Pillow-core compatibility | Run a production-representative trial with the intended core shape, mold or filling arrangement, and production cycle. | Record core dimensions, fill mass, visible defects, cycle time, and results from density and IFD testing. | Check that the equipment can handle the required core geometry, production rate, material delivery, cleaning routine, and operator workflow. | Approve equipment using representative trials and the buyer’s quality criteria, not machine capacity alone. |