| 1. Identify the service | Determine what will flow through the hose and where it will be installed: fuel, potable water, cooling water, bilge water, sanitation, or wet exhaust. | A hose suitable for water service is not automatically suitable for fuel, sanitation, or hot exhaust. Check the product’s stated application and applicable marine hose standard; examples include ISO 7840 for small-craft fuel hoses and SAE J2006 for marine wet-exhaust hose. | Hose liners, reinforcement, and covers are designed for particular fluids, temperatures, and installation conditions. |
| 2. Match the inside diameter | Measure the hose-barb or connection’s nominal size and confirm whether the fitting size refers to the hose’s inside diameter. Check the space available for bends and clamps. | Common nominal inside diameters include 1/2 in (12.7 mm), 3/4 in (19.1 mm), 1 in (25.4 mm), and 1 1/2 in (38.1 mm). These are size examples, not a recommendation for a specific system. | An undersized hose can restrict flow; a poorly matched hose and fitting can make a secure connection difficult. |
| 3. Check pressure ratings | Compare the hose’s rated working pressure with the system’s maximum operating pressure, including relevant pump or operating conditions. Check whether the rating changes with temperature. | Use the manufacturer’s working-pressure rating, not its burst-pressure figure, as the service limit. For unit conversion, 1 bar is approximately 14.5 psi. | Pressure ratings are product- and temperature-specific. A burst rating is not an allowable continuous operating pressure. |
| 4. Match the temperature range | Consider both the fluid temperature and the temperature around the hose, including engine spaces, exhaust routing, and seasonal conditions. | Check the published minimum and maximum service temperatures for the exact hose and application. Do not assume that two hoses with the same diameter have the same temperature capability. | Heat or cold outside the specified range can reduce hose performance and service life. |
| 5. Verify vacuum resistance | If the hose is on a suction line or may experience negative pressure, look for a stated vacuum or suction rating at the relevant temperature and bend radius. | A pressure rating alone does not establish vacuum suitability. Use a hose specifically rated for the system’s expected vacuum conditions. | A hose without adequate reinforcement may flatten or collapse under suction, restricting flow. |
| 6. Check routing and bend radius | Plan the route before ordering. Check the specified minimum bend radius, hose length, movement, chafe points, and clearance from hot or moving components. | Measure the installed route with allowance for the fitting engagement and movement required; do not force a bend tighter than the hose’s published minimum radius. | Kinks, tension, abrasion, and tight bends can damage the hose or limit flow. |
| 7. Match fittings and inspect compatibility | Confirm fitting type, barb size, clamp compatibility, hose wall thickness, and resistance to the fluid and surrounding environment. | Use marine-suitable fittings and clamps appropriate to the hose and location. Follow the hose and fitting instructions for insertion depth, clamp position, and installation. | A correctly rated hose can still leak or fail if the connection is incompatible, incorrectly assembled, or exposed to corrosion or chafing. |