| Fixed capacitor bank | Loads with relatively steady reactive-power demand, such as continuously operating motors | Capacitors provide reactive power locally to offset part of an inductive load’s demand. | Simple arrangement; can be economical for stable loads. | May overcorrect when the load is switched off or falls substantially. Switching and protection must suit the application. | Load profile; motor operating pattern; capacitor switching method; protection and discharge requirements. |
| Automatic switched capacitor bank | Facilities with changing loads, including many commercial and industrial installations | A controller switches capacitor steps in or out in response to measured power factor or reactive power. | Adjusts compensation as demand changes and can help maintain a configured target. | Step size, switching frequency, controller settings, and measurement location affect performance. | Minimum and maximum load; target power factor; number and size of steps; switching-device duty. |
| Detuned capacitor bank | Installations where harmonic-producing equipment is present and capacitor resonance is a concern | Reactors are connected with capacitor stages to shift the circuit’s resonance characteristics. | Can reduce the risk of harmful resonance and support power-factor correction in suitable systems. | Requires a harmonic assessment and correctly engineered component ratings; it does not eliminate all harmonics. | Harmonic measurements; system impedance; background distortion; reactor and capacitor ratings. |
| Active harmonic filter with reactive-power control | Sites with variable nonlinear loads, such as adjustable-speed drives or electronic power supplies | Power electronics inject compensating current to address selected current harmonics and, when configured, reactive current. | Can respond dynamically to changing load conditions and address more than one power-quality issue. | Performance depends on device capacity, system configuration, and control settings; it is not a substitute for engineering assessment. | Load-current spectrum; required compensation; connection point; available fault level; equipment capacity. |
| Synchronous condenser | Large power systems or facilities requiring controllable reactive-power support | An over-excited synchronous machine supplies reactive power; its output can be varied through excitation control. | Provides adjustable reactive support and can contribute rotating inertia to the system. | Higher mechanical and maintenance complexity than capacitor-based solutions; requires a suitable installation and operating plan. | Reactive-power range; operating duty; site and maintenance requirements; system stability objectives. |
| Hybrid correction system | Sites with both rapidly changing loads and steady reactive-power demand | Combines capacitor steps with a dynamic compensator or filter so each component addresses an appropriate part of the demand. | Can balance steady-state compensation with faster response where the design and controls are properly coordinated. | Coordination, protection, harmonic interactions, and control strategy require system-level design. | Time-varying load data; harmonic study; response requirements; operating modes; expansion plans. |